Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 337-344, 2023.
Article in Chinese | WPRIM | ID: wpr-961339

ABSTRACT

Objective @#To evaluate the effect of anatomical healing abutments for mandibular first molars on the morphological changes of gingival soft tissue after implant restoration, as well as on peri-implant gingival molding, food ingrowth and patient satisfaction, to provide a basis for clinical selection. @*Methods @# Twenty-six patients who received implant restoration for a single missing mandibular first molar between September 2020 and September 2021 at the Oral Implant Center of Changsha Stomatological Hospital were randomly divided into a control group (13 cases with 14 implants) and a trial group (13 cases with 14 implants), of which 12 were male and 14 were female; the trial group had anatomical healing abutments applied for 4 weeks and then underwent crown restoration, while the control group finished five time points (before the second stage surgery, 4 weeks after the second stage surgery, immediately after the crown restoration, 4 weeks after the crown restoration, and 12 weeks after the crown restoration). A 3Shape intraoral scanner was used to scan the jaw before and 4 weeks after the second stage surgery to quantify the soft tissue changes and compare the effect of the healing abutment on gingival molding between the two groups. The incidence of food impaction was recorded and compared between the two groups at 4 weeks and 12 weeks after crown restoration. Patient satisfaction was recorded and compared between the two groups immediately after crown restoration, 4 weeks after crown restoration and 12 weeks after crown restoration@*Results @# Four weeks after implant surgery, it was observed that the gingival proximal and distal gingival papillae increased on the coronal side in the test group compared to the control group, 0.50 (0.26, 0.72) mm in the near-medium test group and 0.27 (0.24, 0.38) mm in the control group, with a statistically significant difference (P = 0.029), and 0.48 (0.26, 0.62) mm in the far-medium test group and 0.23 (0.13, 0.39) mm in the control group, with a statistically significant difference (P = 0.004). There was no statistically significant difference (P>0.05) in the buccolingual to gingival margin apex to coronal molding or in the buccolingual to lingual soft tissue at 0, 1, or 2 mm of the root of the middle 1/3 apex of the buccal and lingual gingival margins between the two groups. Compared to the control group, there was no statistically significant difference in the incidence of food impaction observed 4 weeks and 12 weeks after crown restoration in the test group (P>0.05). The satisfaction scores were higher in the trial group than in the control group immediately, 4 weeks, and 12 weeks after crown restoration, and the difference between the groups was statistically significant (P < 0.05). @*Conclusion @# The anatomical healing abutment for the implant mandibular first molar was superior to the finished healing abutment in terms of soft tissue contouring with an increase in the coronal aspect of the proximal and distal gingival papillae, resulting in high patient satisfaction.

2.
Chinese Journal of Stomatology ; (12): 73-79, 2020.
Article in Chinese | WPRIM | ID: wpr-799354

ABSTRACT

Objective@#To establish a quantitative three-dimensional method based on intraoral scan to evaluate the changes of soft tissue, and to evaluate the changes of supracrestal gingival thickness (SGT) in skeletal class Ⅲ patients induced by periodontal regenerative and corticotomy surgery (PRCS).@*Methods@#Twenty-two systematically and periodontally healthy skeletal class Ⅲ patients (4 males and 18 females, aged between 19 and 35 years), who were in need of combined orthodontic-orthognathic treatment and referred to the Department of Periodontology from the Department of Orthodontics and the Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology from January, 2018 to March, 2019, were collected in the study. The teeth involved were 112 anterior teeth (46 maxillary anterior teeth and 66 mandibular anterior teeth). PRCS in anterior tooth area was conducted before orthodontic decompensation. Probing depth (PD), bleeding index (BI) and keratinized gingiva width (KGW) were recorded before surgery and 6 months post-surgery. The intraoral digital impressions of maxillary and mandibular anterior teeth were obtained by 3-shape intraoral scanner before surgery and 6 months after surgery. The Standard Tessellation Language (STL) files were processed using Geomagic qualify 12.2 software to establish the soft tissue morphological measurement model, and to quantitatively analyze the changes of gingival thickness situated 1 to 2 mm apical to the free gingival margin on the median sagittal measurement plane.@*Results@#Probing depth and bleeding index had no significant difference before and 6 months after operation (P>0.05). KGW in 6-month post-operation group [(5.18±2.32) mm] was significantly higher than that in pre-operation group [(4.22±1.43) mm] (P<0.05). Supracrestal gingival thickness situated 1 to 2 mm apical to the free gingival margin also significantly increased 6 months after surgery (P<0.05). The changes of gingival thickness situated 1 to 2 mm apical to the free gingival margin in the upper anterior area were (0.68±0.56) and (1.00±0.69) mm, respectively. The changes in the lower anterior area were (0.38±0.42) and (0.58±0.45) mm, respectively. The gingival changes of the upper anterior teeth were also significantly higher than those of the lower anterior teeth (P<0.01).@*Conclusions@#The described quantitative measurement based on intraoral scan could be an effective method for quantitative evaluation of the changes of soft tissue. PRCS could safely increase the supracrestal gingival thickness as well as KGW in skeletal class Ⅲ patients who were in need of combined orthodontic-orthognathic treatment.

3.
Journal of Peking University(Health Sciences) ; (6): 964-970, 2020.
Article in Chinese | WPRIM | ID: wpr-942105

ABSTRACT

OBJECTIVE@#To evaluate the digital workflow coupling conic retention for the immediate restoration of adjacent posterior implants.@*METHODS@#The patients with adjacent teeth missing in the posterior jaw seeking for implant restoration in the Department of Implantology, Peking University School and Hospital of Stomatology from March, 2017 to February, 2018 were recruited. After implant placement and commercial conic retention coping delivery, the patient had an intraoral scan for digital impression, and the computer-assisted design/computer-assisted manufacturing (CAD/CAM) technology was used for the fabrication of the immediate splinted prosthesis, which was made of polymethyl methacrylate (PMMA) and loaded immediately after delivery. Six months later, all the temporary prostheses were replaced by the permanent ones made of monolithic zirconia with CAD/CAM technology as well. The parallel periapical films were taken for the temporary and permanent prostheses post-delivery. The clinical effect of this workflow was evaluated by indices including the survival rates of implants and prostheses, the change of marginal bone level, and the implant-related and prosthesis-related complications; before the final restoration, the Visual Analogue Score (VAS) was used to evaluate the satisfaction of the patients.@*RESULTS@#Ten patients (4 males and 6 females, 55.5 years old for average) were recruited. Totally 34 implants were placed; 14 prostheses were fabricated, temporary and permanent, respectively. After an observation period from 4 to 14 months, the survival rate for implants and prostheses were both 100%; the marginal bone level of the implants were (1.06±0.97) mm and (0.96±0.82) mm, immediate post-operation and 6 months later, respectively. The difference was not statistically significant (P>0.05). Neither implant- nor prostheses- related complications were observed. And the VAS of the patients' satisfaction was 87.2.@*CONCLUSION@#For the adjacent posterior implants, the immediate prostheses manufactured by digital workflow, coupling conic retention, were clinically feasible and patient-satisfactory.


Subject(s)
Female , Humans , Male , Middle Aged , Computer-Aided Design , Patient Satisfaction , Prostheses and Implants , Prosthesis Implantation , Workflow
4.
The Journal of Korean Academy of Prosthodontics ; : 425-431, 2019.
Article in English | WPRIM | ID: wpr-761449

ABSTRACT

This clinical case report describes the digital workflow that combines a face scan, cone beam computed tomography and an intraoral scan to visualize the outcome of prosthodontic treatment in the anterior region. This approach improves communication between clinic, laboratory and patients. A patient with healthy general condition came for a restorative treatment to treat post-traumatic central incisors of maxilla. A virtual patient replica was made by incorporating a face scan, cone beam computed tomography and an intraoral scan. Design mockup of definitive restorations was shown to the patient and modified according to the patient's desire. This digital workflow facilitates the fabrication of optimal esthetic restorations, and enhances the predictability of outcome of restorations.


Subject(s)
Humans , Cone-Beam Computed Tomography , Incisor , Maxilla
5.
The Journal of Korean Academy of Prosthodontics ; : 432-438, 2019.
Article in Korean | WPRIM | ID: wpr-761448

ABSTRACT

Accurate impression taking for the success of implant prosthesis is a very important process. Methods of taking implant impression include the conventional method using impression coping and impression material, and the digital method using an intraoral scanner and scanbody. However, the impression coping or the scanbody must install after remove healing abutment. Because of this, the dentist must repeat the process of removing and installing the healing abutment, the impression coping or the scanbody several times. In addition, the impression coping or the scanbody rises higher than the occlusal surface, so the patient has the inconvenience of constantly maintaining the open state. Recently, a scannable healing abutment, which can be scanned by a intraoral scanner directly, without the need to remove the healing abutment by applying a scannable part of the scanbody to the healing abutment, was introduced. We present a case of single posterior implant prosthesis using a scannable healing abutment.


Subject(s)
Humans , Dentists , Methods , Prostheses and Implants
6.
Chinese Journal of Stomatology ; (12): 230-235, 2018.
Article in Chinese | WPRIM | ID: wpr-809887

ABSTRACT

In recent years with the rapid development of digital technology for stomatology, the application field, application model, technical features and technical connotation of the chair-side digital technology has got development and change. The open modular system has gradually replaced the traditional closed system, and the application field of digital technology is no longer limited to chair-side dental restoration, it also has been extend to various kinds of chair-side digital treatment-assisted technology. In this paper, from the engineering point of view, the up to date general connotation of chair-side digital technology was explained, the characteristics and the development of each unit in chair-side digital technology were analyzed, and the application pattern and the localization status were also discussed in this paper. The aim of this paper was to introduce the trend of chair-side digital technological to readers and to better guide clinical application.

7.
The Journal of Korean Academy of Prosthodontics ; : 61-70, 2017.
Article in Korean | WPRIM | ID: wpr-39476

ABSTRACT

In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.


Subject(s)
Humans , Dentures , Osseointegration , Prostheses and Implants
8.
The Journal of Korean Academy of Prosthodontics ; : 135-143, 2017.
Article in English | WPRIM | ID: wpr-91674

ABSTRACT

PURPOSE: This research was conducted to compare the marginal and internal fit of zirconia prostheses fabricated with the model scan method and the intraoral scan method. MATERIALS AND METHODS: In this study, 20 extracted human mandibular first molar was used in the preparation of abutment tooth for the fabrication of zirconia prostheses. In the first group, the model scan method was applied on 10 prepared teeth. In the other group, the intraoral scan method was used on other 10 prepared teeth. Datum of both groups were transmitted to the software system. Afterwards, 20 zirconia prostheses were fabricated using the Ceramill system. Weight technique was used to evaluate the internal gap of the zirconia prostheses. In the Replica technique, marginal gap of the zirconia prostheses were analyzed by optical microscopy. Statistical analysis was based on one-way ANOVA. RESULTS: Model scan group showed lower average weight than intraoral scan group when weight technique was applied, which has significance (P < .05). Also, model scan group showed significantly lower figures in all 5 measurements of replica technique than intraoral scan group (P < .05). CONCLUSION: Zirconia prostheses of both groups demonstrated clinically acceptable margin and internal fit. However, model scanned zirconia prostheses showed higher marginal and internal fit than intraoral scanned crowns.


Subject(s)
Humans , Crowns , Methods , Microscopy , Molar , Prostheses and Implants , Replica Techniques , Tooth
9.
The Journal of Korean Academy of Prosthodontics ; : 157-166, 2015.
Article in Korean | WPRIM | ID: wpr-87261

ABSTRACT

This article describes how to use CBCT and an intraoral scanner in a fully edentulous case that enables the clinician to place implants with flapless guided surgery and to engage prefabricated, customized implant abutments at the time of implant surgery, with only 1 clinical consultation before implant surgery. The patient's existing denture is used to simulate the teeth, the soft tissue and the vertical dimension of occlusion, and jaw relationship in the fully edentulous jaw. It provides clinicians with a fast workflow and improves clinical efficiency.


Subject(s)
Humans , Dentures , Jaw , Jaw, Edentulous , Tooth , Vertical Dimension
10.
The Journal of Korean Academy of Prosthodontics ; : 256-261, 2015.
Article in Korean | WPRIM | ID: wpr-39282

ABSTRACT

Accuracy is the most important thing in implant prosthesis, for this reason it is essential procedure to check the accuracy of impression taking. However, impression material has its own error and the error occurs in model-making procedure. As an alternative way to this, using intraoral scanner can be suggested and many studies were issued reporting that there's no statistically significant difference in accuracy between intraoral scanner and conventional impression. Therefore, the purpose of this study is to report the process of making of implant prosthesis using intraoral scanner, which is more convenient, fast, accurate compared with conventional method.


Subject(s)
Prostheses and Implants
SELECTION OF CITATIONS
SEARCH DETAIL